Houses one very large AI training job on a building complex with accelerators on a single network, a city-scale power system and cooling.

Stargate Abilene, xAI Colossus, Meta Hyperion

Open the gigawatt-ai-campus pagegigawatt-ai-campus Datacenter coolingcloud: Hot/cold aisle containment, free cooling, direct liquid cooling and PUE mathPower oversubscription cappingcloud: Oversubscribe datacenter power with telemetry and fast capping (RAPL, priority-based throttling)Ups power distributioncloud: UPS, PDUs, busways and redundancy schemes (N+1, 2N) for datacenter powerGorilla XOR compressioncompression: Time-series codec: delta-of-delta timestamps plus XOR of consecutive float bit patterns, storing only changed bits; about 1.4 bytes per point.›Gang schedulingdistributed: All-or-nothing co-scheduling of a job's tasksBattery state estimationembedded: State of charge / health / power from coulomb counting, OCV curves and model-based observersDroop controlembedded: Frequency/voltage droop: proportional power response that lets inverters share load without communicationBmc out of band managementhardware-os: IPMI/Redfish BMC control: power, boot device, sensors, serial-over-LANPower management dvfshardware-os: DVFS governors, P- and C-states, race-to-idle, thermal throttlingCollective communicationml-training: The family of group exchanges (broadcast, reduce, all-gather, reduce-scatter, all-to-all) and the latency-plus-bytes cost model that picks ring, tree or direct algorithms by message size and topology.›Distributed checkpointingml-training: Sharded, asynchronous checkpoint save/load of model and optimizer state, with resharding to new world sizesGpu health checksml-training: Detecting bad GPUs/links before and during jobs: ECC/XID errors, NCCL tests, throughput probes, drainingRing all-reduceml-training: Sum a buffer across N workers via reduce-scatter then all-gather around a ring; each link carries 2(N−1)/N of the buffer, which is bandwidth-optimal.›Datacenter congestion controlnetworking: ECN-based schemes for RDMA and DC TCP: DCQCN, DCTCP, HPCC, plus PFC lossless pitfallsIn network aggregationnetworking: Reduce gradients or data inside switches (SHARP, SwitchML) to cut allreduce trafficNetwork topologiesnetworking: Fat-tree and Clos, dragonfly, torus and rail-optimized topologies: bisection bandwidth and diameterRdmanetworking: RDMA verbs over InfiniBand/RoCE: queue pairs, memory registration, one-sided opsFinite volume methodnumerics: Conservative cell-averaged discretization with numerical fluxes on structured and unstructured meshesVector bin packingoptimization: Multi-dimensional bin packing heuristics (first fit decreasing, dot product) for placing VMs and jobsModel predictive controlrobotics: Each tick, solve a small optimization over a predicted horizon, apply only the first input, repeat. Handles constraints and multiple inputs that a PID loop cannot.›PID controllerrobotics: Drive a measured value to a setpoint with three terms on the error: proportional, integral, derivative. The default feedback loop for motors, heaters, drones and gimbals.›Time-series anomaly detectionstatistics: Predict the expected value from a seasonal baseline, scale the residual by a robust spread (MAD), threshold at a chosen false-alarm rate, then merge flags into incidents.›Bacnet protocolembedded: BACnet objects, properties and services over IP/MSTP for building automationAlarm managementembedded: Turn raw process limits into a few actionable operator alarms with delay, deadband, acknowledge and shelving states, plus flood measurement.›Modbus protocolembedded: Modbus RTU/TCP registers and function codes with polling and CRCHot-standby redundancyembedded: A second, always-current controller shadows the primary and takes over within a few cycles of silence; epochs stop the old primary from fighting back.›Priority and preemptionsystems: Priority classes, quota and evicting lower-priority work to admit higherDelta encodingcompression: Store differences between consecutive values instead of the values, turning sorted IDs, timestamps and counters into small numbers that pack into few bits.›Bitstream serializationgame-networking: A bit writer and reader over a byte buffer that stores each field in exactly the bits its range needs: booleans in 1 bit, bounded integers in ceil(log2(span+1)) bits.›Distributed barrierdistributed: Rendezvous/barrier for a dynamic worker group: join, agree on membership and rank assignment, restart on changeTopology aware placementsystems: Place work by NUMA, rack, zone and GPU interconnect topologyEquivalent circuit batterymodelembedded: Thevenin RC-network battery models with OCV-SoC curves and parameter identificationSpline interpolationnumerics: Linear, bilinear/trilinear and cubic spline interpolation on grids and tablesExtended Kalman filterrobotics: Kalman filter for nonlinear motion and measurement models: linearize f and h with Jacobians at the current estimate each step. The default estimator in robot navigation.›+ 25 moreDebouncing throttlingsystems: Coalescing rapid events: debounce (wait for quiet), throttle (max rate), and cancelling stale in-flight requestsHierarchical state machinesystems: Nest states so a substate inherits its parent's reactions and only overrides what differs, with ordered entry and exit actions along the path.›Primary-backup replicationdistributed: One node orders all writes and ships them to standbys; the acknowledgement rule (none, one, all) sets what a crash loses, and an external arbiter decides who takes over.›Watchdog timerembedded: A hardware down-counter that resets the chip unless software proves, in time and in a plausible pattern, that it is still healthy.›d-ary heapdata-structures: Array heap with d children per node (d = 4 typical): half the binary heap's depth, siblings in one cache line, faster priority queues.›Resource usage accountinghardware-os: Cgroup/procfs/GPU counters sampled into per-workload usageGraceful drainingsystems: On a termination signal, stop taking new work, finish in-flight work until a deadline, tell clients to reconnect elsewhere, then exit; clients resume from a token.›Bit packing and PFORcompression: Store blocks of integers with exactly b bits each and patch rare outliers separately (PFOR); the fastest integer codec family, billions of values per second.›Varint (LEB128)compression: Variable-length integers in 7-bit groups with a continuation bit; small numbers take 1 byte, the wire format of Protobuf, WebAssembly and DWARF.›Numa aware allocationhardware-os: Allocate memory and pin threads on the local NUMA node; first-touch and interleave policiesExplicit Eulernumerics: Step an ODE forward by its current slope, y += h·f(t, y); first-order, one evaluation per step, the baseline every other integrator is measured against.›Levenberg marquardtnumerics: Damped Gauss-Newton nonlinear least squares for model calibration+ 18 moreLeasesdistributed: A lock that expires on its own: bounded-time ownership that survives crashes and partitions, given bounded clock drift and fencing tokens on writes.›Write-ahead logstorage: Append each change to a checksummed sequential log and fsync it before touching data pages; the basis of crash durability in nearly every database.›Health checkingsystems: Decide per backend whether to route to it using probes and real-traffic errors, with consecutive-count hysteresis, capped ejection and a panic fallback.›SIMD programminghardware-os: Process 4-16 lanes per instruction with AVX2, AVX-512 or NEON via Rust std::arch, with runtime dispatch and a portable fallback.›+ 5 moreFencing tokensdistributed: A number that grows with every lock grant and is checked by the protected resource, so a paused ex-holder's late write is rejected.›CRC32C checksumshardware-os: The Castagnoli CRC-32 with dedicated instructions on x86 (SSE4.2) and ARMv8. It is the standard fast integrity check for storage blocks, logs and network frames.›fsync, O_DSYNC and O_DIRECThardware-os: What fsync, fdatasync, O_DSYNC, O_DIRECT and F_FULLFSYNC really guarantee on Linux and macOS, and the exact call sequences for crash-safe files.›+ 1 more+ 1 more

How it is built

Architecture overview

A gigawatt AI campus is one training job's machine, built as a building complex: tens to hundreds of thousands of accelerators on one low-latency network, fed by a power system the size of a small city and cooled by a plant that must keep every chip inside its thermal limit. The jobs are synchronous: every accelerator computes, then all of them exchange gradients, then repeat. That single fact shapes everything. The network must behave like one big switch, a single slow or dead GPU stalls thousands of others, the power draw swings in step across the whole site, and the useful output is measured as the share of wall-clock time that training really progresses. The idea that makes it work is to treat the campus as one control system with three coupled loops (power, heat, data) and one job scheduler on top, so a fault or a power swing in one loop is absorbed before it reaches the training job. Public examples are xAI's Colossus in Memphis, the OpenAI/Oracle Stargate site at Abilene and Meta's Llama training clusters (source: NVIDIA newsroom, 28 Oct 2024; Wikipedia, Colossus, Stargate LLC; Llama 3 paper).

Parts:

  • Power chain — grid or onsite generation, UPS, distribution, battery buffers — ups-power-distribution (no page yet), battery-state-estimation (no page yet), droop-control (no page yet)
  • Power management — budgets, capping and smoothing of the load — power-oversubscription-capping (no page yet), power-management-dvfs (no page yet)
  • Cooling — heat removal from chip to outdoors, and its controller — datacenter-cooling (no page yet), PID controller, Model predictive control, finite-volume-method (no page yet)
  • Telemetry and anomaly detection — per-second sensor streams from chips, racks and plant — Gorilla XOR compression, Time-series anomaly detection
  • Machine management — out-of-band control of every server and health screening of every GPU — bmc-out-of-band-management (no page yet), gpu-health-checks (no page yet)
  • Network fabric — topology, RDMA transport, congestion control — network-topologies (no page yet), rdma (no page yet), datacenter-congestion-control (no page yet)
  • Collectives — the gradient exchange itself — Collective communication, Ring all-reduce, in-network-aggregation (no page yet)
  • Scheduling and recovery — placement, gang start, checkpoints — vector-bin-packing (no page yet), gang-scheduling (no page yet), distributed-checkpointing (no page yet)
 grid / on-site gen ──► UPS + battery ──► rack power ───────┐
        ▲  droop / ramp limits        (smoothing, capping)  ▼
        │                                             ┌─ server (BMC, GPUs) ─┐
 chillers, CDUs ◄── heat ◄───────────────────────────│ 8 GPUs, NVLink       │
   ▲ PID / MPC                                        └──────┬───────────────┘
   │                                    RDMA fabric (leaf → spine → aggregation)
 telemetry ◄── power, temperature, GPU health ─────── congestion control, collectives
   │                                                         │
   └────────► anomaly detection ──► scheduler ──► drain, gang restart, checkpoint

There are two time scales in one site. The training loop runs in seconds with sub-second power and network dynamics. The facility runs in minutes to years: chiller response, firmware upgrades, hardware replacement. Most of the engineering is the interface between the two.

How the parts fit together

Power chain and the grid

Each GPU in the Llama 3 405B training cluster is rated at 700 W TDP (source: Llama 3 paper), so a server of eight draws several kilowatts before cooling and network overhead; in a GB200 server GPUs account for more than half the provisioned power (source: Choukse et al., 2025). Multiplied by the rack count that reaches hundreds of megawatts and then a gigawatt. The grid connection often arrives later than the buildings: for Colossus, Wikipedia reports an initially limited grid connection, with temporary gas turbines and Tesla Megapack batteries filling the gap. So the power chain is a mix of sources, each with its own control behaviour.

UPS power distribution (no page yet) is the layer that carries the load through short interruptions and conditions the supply to the racks. Droop control (no page yet) is how several generators or inverters share a load without a central controller: each lowers its frequency or voltage slightly as its output rises, so they settle at shares proportional to their ratings. A campus with on-site generation is a small grid, and the training job is a violently varying load on it. Batteries between the grid and the racks need a state estimate (charge, health, temperature); Battery state estimation (no page yet) supplies it, typically with a Kalman-type filter on voltage and current (see Kalman filter), so the smoothing system knows how much energy it can really absorb or release.

Power management: oversubscription, capping and smoothing

Two opposite problems sit here. The first is headroom. Fan, Weber and Barroso measured thousands of servers over six months and found a gap of 7 to 16 % between achieved and theoretical aggregate peak power at cluster level, growing to almost 40 % in whole datacenters, which suggests deploying more equipment than the nameplate budget allows (source: Fan et al., ISCA 2007). Power oversubscription and capping (no page yet) is the mechanism: plan on measured aggregate demand, and hold a capping layer ready to cut the load if the sum approaches the limit. Power management with DVFS (no page yet) is the knob a cap turns: lower frequency and voltage reduce power at a performance cost. Llama 3's authors note that hot mid-day weather made GPU dynamic frequency scaling cost 1 to 2 % of throughput (source: Llama 3 paper): the power and cooling loops leak into training speed.

The second problem is the swing. Synchronous training alternates a compute-heavy phase and a communication-heavy phase, and the compute phase draws much more power. When tens of thousands of GPUs do this together, the aggregate swings by tens of megawatts, and the Meta paper lists checkpoint waits and job start or stop as other synchronous events (source: Llama 3 paper). Choukse et al. show that at scale the swings reach tens or hundreds of megawatts and that their frequency, if it matches resonant modes of the grid and of turbine-generator shafts (they cite a 1 to 20 Hz band, with concern around 2 to 3 Hz), can damage equipment, so utilities specify ramp rates and frequency limits (source: Choukse et al., 2025). Their mitigations come in three layers: software that injects filler work to flatten the dip, GPU firmware with power floors and ramp limits, and rack-level energy storage that absorbs and releases the difference. The headroom of the first problem is thus largely gone for training sites: synchronised jobs do not average out the way independent web workloads do. Software and floors waste energy; storage costs hardware; sites use more than one layer.

Cooling and its control

Almost all electrical power ends up as heat, and the plant must remove it before any chip throttles. Datacenter cooling (no page yet) covers the path from chip to outdoors; efficiency is reported as power usage effectiveness (PUE), the ratio of total facility energy to the energy delivered to computing equipment (source: Wikipedia, Power usage effectiveness). Controllers close loops on supply temperature and flow. PID controller is the baseline for each loop (pump speed, valve position); Model predictive control can coordinate loops with coupled dynamics and a known disturbance, here the planned job schedule. Slow thermal mass is what makes prediction pay: the cooling plant can pre-cool before a known power rise. Finite volume method (no page yet) is the offline tool: computational fluid dynamics of airflow or coolant distribution, used to place racks and check hot spots before the building exists, and sometimes as a reduced model inside the predictive controller.

Telemetry and anomaly detection

Every chip, rack, pump and breaker emits metrics, often once per second or faster, and the stream is retained for post-mortems. Gorilla XOR compression is the time-series storage idea suited to it: consecutive floating-point values are XOR-ed and mostly zero bits are stored, so a slowly changing temperature costs a few bits per sample. Time-series anomaly detection turns the streams into alerts: a GPU slowly running hotter than its neighbours, a link whose error counter climbs, a pump whose power drifts. At this scale a rule per sensor is impossible, so detectors compare each device with its peers in the same rack or job.

Machine management and health

Each server has a baseboard management controller (BMC): a small computer on its own network that can power-cycle the host, read sensors and update firmware without the host's operating system. BMC out-of-band management (no page yet) is that layer; OpenBMC is a Linux distribution for such controllers and DMTF's Redfish is a standard management API (source: OpenBMC repo; DMTF Redfish developer hub). GPU health checks (no page yet) run before a job starts and on a schedule: NVIDIA's DCGM exposes health checks and diagnostics for GPU, board and environment (source: DCGM docs). The cost of skipping them is large. Meta's team reports 466 job interruptions in 54 days of Llama 3 405B pre-training, 419 unexpected, about 78 % attributed to confirmed or suspected hardware issues, and notes that a single straggler can slow thousands of other GPUs (source: Llama 3 paper). A separate study of two research clusters (4 million jobs, over 150 million A100 GPU hours in 11 months) finds large jobs most vulnerable to failure (source: Kokolis et al., 2024).

Network fabric

Training traffic is large, synchronised and loss-sensitive. Network topologies (no page yet) for these sites are multi-tier fat trees. Meta's RoCE cluster for Llama 3 has 16 GPUs in a rack, 192 racks per pod for 3,072 GPUs with full bisection bandwidth, and eight pods for a 24K-GPU cluster, with 400 Gbps links (source: Llama 3 paper). RDMA (no page yet) lets one GPU's network card write to another's memory without involving the CPU. Over IP networks it runs as RoCEv2, which relies on priority flow control to avoid loss; datacenter congestion control (no page yet) keeps that from stalling the whole fabric, as in DCQCN (source: Zhu et al., SIGCOMM 2015). Large training flows are few and fat, which defeats plain ECMP hashing; Meta added more entropy fields in the RoCE header to spread them (source: Llama 3 paper). NVIDIA reports that xAI's 100,000-GPU Colossus kept 95 % throughput across its three tiers with Spectrum-X, against about 60 % for standard Ethernet (source: NVIDIA newsroom). These are vendor figures; the point is that fabric tail latency is a first-order design target.

Collectives

The fabric exists to run Collective communication such as all-reduce, all-gather and reduce-scatter. Ring all-reduce moves each gradient around a ring in chunks so every link is busy and bandwidth per GPU stays constant as the ring grows; the Horovod paper popularised it for deep learning (source: Sergeev and Del Balso, 2018). Latency grows with ring length, so large jobs use trees, hierarchies and topology-aware layouts. Meta's collective library for Llama 3 is a fork of NCCL, and its parallelism dimensions are ordered so the chattiest traffic stays on the fastest links (source: Llama 3 paper). In-network aggregation (no page yet) moves the reduction into switches (SHArP, Graham et al. 2016), at the cost of switch features that tie you to a vendor.

Scheduling, gang start and checkpoints

A synchronous job needs all its GPUs or none. Gang scheduling (no page yet) starts all members together; in Kubernetes ecosystems Volcano has a "gang" plugin that checks whether the minimum pods can run, and Kueue manages quotas and admission (source: Volcano docs; Kueue docs). Vector bin packing (no page yet) places jobs on racks and pods: each job is a vector of GPUs, host memory and network, and fragmentation of one dimension strands the others. Placement is topology-aware so a job stays inside as few pods as possible.

Failures at the rate above make Distributed checkpointing (no page yet) essential. Meta's checkpoints save each GPU's model state, 1 MB to 4 GB per GPU, to a distributed file system (240 PB, 2 TB/s sustained, 7 TB/s peak) and the bursty writes were a challenge for the storage fabric (source: Llama 3 paper). Faster and more frequent checkpoints reduce lost work but also create synchronous power events, which closes the loop with the power section. Llama 3 reached over 90 % effective training time with automated maintenance, which caused at least one interruption daily (source: Llama 3 paper).

Data and control flow

One training step, seen from the campus:

  1. Every GPU computes forward and backward passes on its shard; power rises toward TDP.
  2. Gradients are reduced through the collective library over the RDMA fabric; GPUs idle during the exposed part and power drops.
  3. The optimiser updates, the next step starts, and power rises again. The loop repeats at the step period.
  4. The power layer sees the aggregate: cap and smoothing act on ramp rates, storage covers the difference.
  5. Cooling responds slowly to the average, not the swing; telemetry samples all of it, and anomaly detection compares each GPU with its peers.

One failure, from fault to restart:

  1. A GPU, link or host fails or becomes a straggler; the collective stalls or slows.
  2. A watchdog in the training framework or the health check flags the member; the scheduler drains the host.
  3. The BMC power-cycles or isolates it; a spare host is health-checked and reserved.
  4. The job restarts as a gang from the latest checkpoint on the new set of hosts.
  5. Lost work is the time since the last checkpoint plus restart.

Scaling

The binding constraint changes with size.

  1. Time to power. At gigawatt scale the grid interconnect, not the chips, sets the schedule. Levers: onsite generation, batteries, staged energisation.
  2. Power swing. Pull the three smoothing layers in the order of cost: software and firmware floors first, then storage.
  3. Network tail latency. Levers: topology-aware placement, congestion control tuned to the fabric, entropy for load balancing, in-network reduction.
  4. Failure rate. Mean time between interruptions falls with job size. Levers: health checks before and during runs, spares, faster checkpoints, straggler detection.
  5. Cooling and density. Levers: predictive control, and CFD at design time.

Failure modes

FailureSymptomCauseFix
Grid oscillationutility complains, protective tripssynchronous power swing aligned with a grid resonanceramp limits, power floors, rack storage, coordinate with the utility
Stragglerstep time rises with no errorone GPU thermally throttled, a bad link or noisy neighbourper-device step-time telemetry, health checks, drain and replace
Collective hangall ranks wait foreverone rank dead or a link flappingcollective timeout with flight recorder, restart the gang
Congestion collapsethroughput falls under load, pause stormsflow control without end-to-end congestion control, poor hashingcongestion control, more entropy in load balancing, adaptive routing
Silent data corruptionloss spikes or divergence with no hardware errorfaulty GPU computing wrong resultsscreening tests, loss and gradient-norm monitors, quarantine suspects

Real implementations

namewhat it isrepolicencenotes
NCCLGPU collective communication libraryNVIDIA/ncclApache-2.0 (parts BSD)collective base of most large training stacks
Horovoddistributed training framework using ring all-reducehorovod/horovodApache-2.0popularised ring all-reduce for deep learning
DCGMGPU health, diagnostics and telemetryNVIDIA/DCGMApache-2.0health checks for GPU, board and environment
OpenBMCLinux distribution for baseboard management controllersopenbmc/openbmcsee repoout-of-band management; Redfish is the matching API standard
KueueKubernetes-native job queueing and quota systemkubernetes-sigs/kueueApache-2.0admission, preemption, fair sharing
VolcanoKubernetes batch scheduler with a gang pluginvolcano-sh/volcanoApache-2.0gang scheduling for training jobs
SlurmHPC workload manager with gang scheduling and preemptionSchedMD/slurmGPLcommon on research clusters
xAI Colossus, Stargate Abilene, Meta clustersthe campuses themselves——closed; public facts from press and papers cited above

The alternative: several smaller clusters in separate sites joined by a slower wide-area network. It avoids one gigawatt interconnect and one power point of failure, but synchronous training must then tolerate slow gradient exchange between sites. The single campus wins for one very large synchronous run; multi-site wins when power cannot be had in one place.

Sources

  • A. Grattafiori et al., The Llama 3 Herd of Models, 2024. paper
  • A. Kokolis et al., Revisiting Reliability in Large-Scale Machine Learning Research Clusters, 2024. paper
  • E. Choukse et al., Power Stabilization for AI Training Datacenters, 2025. paper
  • X. Fan, W.-D. Weber, L. A. Barroso, Power Provisioning for a Warehouse-sized Computer, ISCA 2007. doi
  • Y. Zhu et al., Congestion Control for Large-Scale RDMA Deployments, SIGCOMM 2015. doi
  • R. L. Graham et al., Scalable Hierarchical Aggregation Protocol (SHArP), COMHPC 2016. doi
  • A. Sergeev and M. Del Balso, Horovod: fast and easy distributed deep learning in TensorFlow, 2018. paper
  • NVIDIA, Ethernet Networking Accelerates World's Largest AI Supercomputer, Built by xAI, 28 Oct 2024. news
  • Wikipedia: Colossus (supercomputer), Stargate LLC, Power usage effectiveness.
  • Docs: NVIDIA DCGM, Volcano plugins, Kueue overview, Slurm gang scheduling, DMTF Redfish.